DayoRN
VENT
VENTILATORS
EDUCATION ONLY
—
ACCURACY (FULLY-CORRECT CASES)
0
BEST STREAK
0
CASES COMPLETED
TOPIC MASTERY0 of 6 topics cleared

A topic clears after 2 correct answers in a row. Miss a question and the topic lands in your revisit list.

CASE 1

DAYORN · SIMULATED VENTILATORTEACHING MODEL

Schematic traces and simulated values for education only — not a medical device, not for clinical use.

Quick reference

Modes: VC guarantees volume · PC guarantees pressure (volume varies) · PS only boosts breaths the patient starts (no set rate) · AC gives a full breath for every trigger · SIMV mixes mandatory + own breaths · CPAP = one pressure, no boost · BiPAP = IPAP/EPAP, the gap ventilates.

Numbers: Vt 4–8 mL/kg IBW · Pplat < 30 cmH2O · PEEP 5–15 · PS 5–15 · SpO2 92–96% (88–95% COPD/ARDS) · RSBI < 105 · MV = rate × Vt drives CO2 · FiO2 + PEEP drive oxygen.

Alarms: peak↑ plateau OK = resistance (plug, kink, spasm) · peak↑ plateau↑ = compliance (edema, pneumothorax, mainstem) · volumes/pressures falling = leak, disconnect, displaced tube · sudden deterioration = DOPE + hand-bag.

Practice questions

These open the actual NCLEX Trainer question bank — the same questions, answers, rationales, and textbook sources used across DayoRN. Work the respiratory set there to broaden beyond ventilator scenarios.

Respiratory questions in the NCLEX Trainer

THIS SESSION

Progress

Saved on this device and, when you're signed in, synced to your account — pick up where you left off on any device.

—
ACCURACY
0
BEST STREAK
0
CASES COMPLETED

Topics to revisit

Nothing missed yet — your misses will collect here.

Account settings

Signed in as —

Discount code

Reset progress

Erases all Ventilators progress on this account — on this device and in the cloud.

Delete account

Permanently deletes your DayoRN account, your username and your Ventilators progress. This cannot be undone.

LEARN THE WHOLE TOPIC

Field guide

The complete ventilator reference for this module — modes, settings, monitoring, waveforms, alarms, ABG-driven adjustments, weaning, and prevention. Every practice chain is keyed to this guide, and every section names its source.

The complete ventilator textbook for this module. Every practice chain in this app is keyed to what is written here — if an answer ever seems to disagree with this guide, the guide wins.

1. Ventilation basics

A ventilator is a machine that moves air in and out of the lungs for a patient who cannot do it well enough alone. The most common reason is acute respiratory failure — either hypoxemic (the lungs cannot get oxygen in, PaO2 < 60 mmHg) or hypercapnic (the lungs cannot clear carbon dioxide, PaCO2 > 50 mmHg) — plus airway protection (a patient who cannot protect their own airway), surgery, and severe metabolic problems where breathing is compensating.

The airway. An endotracheal tube (ETT) passes through the mouth into the trachea; a cuff at its tip seals the trachea so air goes through the tube, not around it. Correct placement is confirmed with end-tidal CO2, auscultation of all lobes, and a chest X-ray. A tracheostomy is a surgical opening directly into the trachea — used when ventilation will be prolonged; it is more comfortable, needs less sedation, and makes suctioning and eventual weaning easier.

The circuit is the tubing from ventilator to patient. It carries gas out to the patient and exhaled gas back. Water condensing in the circuit, kinks, and loose connections are everyday troubleshooting items (see Alarms).

Mandatory vs spontaneous breaths. A mandatory breath is started and/or finished by the machine on a schedule. A spontaneous breath is started by the patient's own effort. Modes differ in how they mix the two — that mix is the single most useful way to understand any mode.

📖 Source: OpenStax, Medical-Surgical Nursing — §35.3 Respiratory Concerns · StatPearls — Ventilator Management

2. Modes — what the vent guarantees

Read every mode the same way: what does the ventilator guarantee, what does the patient control, and what can go wrong?

ModeThe vent guaranteesPatient controlsUsed for / watch-outs
Volume Control (VC)A set tidal volume (Vt) every mandatory breath, whatever pressure it takesNothing about the breath size; may trigger extra breaths (in AC)Predictable minute ventilation. Watch-out: if lungs stiffen, pressures climb — watch plateau pressure.
Pressure Control (PC)A set inspiratory pressure for a set inspiratory time; volume is whatever that pressure deliversNothing about volumeGentle, capped pressures. Watch-out: if compliance falls (stiffer lungs), the same pressure delivers LESS volume — exhaled Vt drifts down.
Pressure Support (PS)A pressure boost added to each breath THE PATIENT starts; the breath ends when the patient's inspiratory flow fallsRate, timing, and (with the boost) much of the volumeWeaning and spontaneous breathing. There is NO set rate and no machine breaths if the patient makes no effort (except a backup in some setups). Too much PS → oversized volumes; too little → rapid shallow fatigue.
Assist Control (AC)A full mandatory breath (set Vt in AC-VC, or set pressure in AC-PC) at a set minimum rate — AND the same full breath for every patient triggerCan trigger extra full breathsFull support for acute respiratory failure; the most common ICU starting mode. Watch-out: a fast patient gets a full breath for every effort → high minute ventilation and respiratory alkalosis.
SIMVA set number of mandatory breaths; breaths the patient takes in between are their own (often with PS added)Extra breaths between the mandatory onesA step-down/weaning structure. Watch-out: unsupported spontaneous breaths through a tube are hard work — add PS, and beware SIMV rates that are neither full support nor a real trial.
CPAPOne continuous pressure, all the time (like PEEP for every breath); no inspiratory boostEverything — rate, timing, volumeNon-invasive (mask) or as a spontaneous trial setting. Helps oxygenation by keeping alveoli open; does NOT directly blow off CO2.
BiPAP (NIV)Two pressures: IPAP on inspiration, EPAP (= PEEP) on expiration; the IPAP–EPAP gap is pressure support by another nameTriggers every breathMask ventilation for COPD exacerbation and cardiogenic pulmonary edema. CO2 problem → widen the gap (raise IPAP). Oxygen problem → raise EPAP/FiO2.
APRV (overview)A high CPAP level held most of the time with brief timed releases to a low pressure; the patient may breathe spontaneously throughoutSpontaneous breaths at both levelsA specialist rescue mode for severe ARDS in some centres. You need to recognise it, not set it.
PS vs PC — the comparison students mix up. Both are pressure-targeted: you set a pressure, and volume is the result. The difference is whose breath it is. Pressure Control delivers mandatory breaths: the machine starts them on a set rate and holds the set pressure for a set inspiratory time, whether or not the patient tries. Pressure Support only supports breaths the patient starts: no patient effort, no breath; no set rate. PC = the machine breathes for the patient at a set pressure. PS = the patient breathes, and the machine pushes behind each effort.

📖 Source: StatPearls — Assist-Control Ventilation · StatPearls — Ventilator Management

3. Settings

SettingWhat it isStandard teaching values
Tidal volume (Vt)Volume per breath, prescribed against ideal body weight (IBW), never actual weight: IBW (kg) ≈ 50 + 0.91 × (height cm − 152.4) for men; 45.5 + 0.91 × (height cm − 152.4) for women4–8 mL/kg IBW (lung-protective; ~6 is the usual starting point)
Respiratory rate (RR)Set breaths per minute (patients may breathe above it in AC/SIMV/PS)Commonly 12–20 to start; adjusted to the ABG
PEEPPressure kept in the airways at end-expiration so alveoli stay openTypical 5–15 cmH2O; an oxygenation lever
FiO2Fraction of inspired oxygen (room air = 0.21)Start high in an emergency, then wean promptly — target SpO2 92–96% for most, 88–95% in COPD/ARDS contexts
I:E ratioInspiratory time vs expiratory timeCommonly 1:2; obstructive patients need a LONGER expiration (1:3, 1:4)
Inspiratory pressureThe set pressure in PC (above PEEP)Titrated to deliver a protective Vt
Pressure support levelThe boost above PEEP for each spontaneous breathTypical 5–15 cmH2O
Trigger sensitivityHow much effort/flow the patient must generate to start a breathToo insensitive → missed efforts; too sensitive → the machine self-triggers (auto-triggering)
Rise timeHow quickly pressure reaches its target at breath startComfort/synchrony setting; too slow can cause air hunger in PS

📖 Source: StatPearls — Acute Respiratory Distress Syndrome (Vt 4–8 mL/kg IBW, SpO2 88–95%, plateau < 30) · StatPearls — Positive End-Expiratory Pressure

4. Monitoring — the numbers that keep lungs safe

Peak pressure (Ppeak) is the highest pressure during the breath — it fights airway resistance AND lung stiffness. Plateau pressure (Pplat), measured with an end-inspiratory hold, is the pressure in the alveoli themselves — the one that stretches lung tissue. Target Pplat < 30 cmH2O. The pattern tells the story: peak up with plateau near normal = a resistance problem (secretions, kink, bronchospasm). Peak AND plateau up = a compliance problem (stiffer lungs — edema, pneumothorax, worsening ARDS).

Driving pressure in plain terms = Pplat − PEEP: how much pressure each breath actually spends stretching the lung. Lower is safer; it rises when you raise Vt or lungs stiffen. Compliance = change in volume ÷ change in pressure — stiff lungs have low compliance. Minute ventilation (MV) = RR × Vt, and it is the master control for CO2. EtCO2 (end-tidal CO2) tracks exhaled CO2 breath by breath: it trends with PaCO2, and SUDDEN loss of EtCO2 means the gas isn't coming back — think displaced tube or disconnect until proven otherwise.

Auto-PEEP (intrinsic PEEP) happens when the next breath starts before exhalation finished, trapping air breath after breath. COPD and asthma patients — narrow airways, slow emptying — are the classic risk, and high rates/short expirations make it worse. Spot it on the flow waveform: expiratory flow never returns to zero before the next breath. Consequences: rising pressures, and the trapped pressure can squeeze venous return and drop blood pressure. Fix = give more expiratory time (lower rate, longer I:E), treat the obstruction.

📖 Source: StatPearls — ARDS (plateau < 30) · StatPearls — PEEP (intrinsic/auto-PEEP) · StatPearls — Ventilator Management (MV = RR × Vt; compliance)

5. Waveforms & asynchrony

Two traces matter most. The pressure scalar: PC/PS breaths rise quickly to a flat top (square-ish); VC breaths climb through the breath. The flow scalar: VC gives a decelerating inspiratory flow; the expiratory side should always drift back to zero before the next breath.

AsynchronyHow it looksFix the cause
Double triggeringOne patient effort pulls two quick machine breaths — the first breath ended before the patient's demand didLonger inspiratory time / more support; treat pain, agitation, hunger for air
Flow starvationThe pressure curve sags/scoops during a VC breath — the patient is pulling harder than the machine deliversIncrease flow (or switch to a pressure mode); treat the drive (pain, acidosis, anxiety)
Ineffective effortsSmall bumps in flow/pressure that never become breaths — the patient tried and the machine didn't noticeMake the trigger more sensitive; reduce auto-PEEP, which forces the patient to overcome trapped pressure first

📖 Source: StatPearls — Ventilator Management

6. Alarms & troubleshooting

High-pressure alarm — think resistance vs compliance again: secretions/mucus plug, kinked or bitten tube, bronchospasm, water in the circuit (resistance family); pneumothorax, worsening edema/ARDS, right-mainstem intubation (compliance family). Low exhaled volume / low pressure — the gas is escaping: circuit disconnect, cuff leak, or a displaced tube. Apnea alarm — no breaths detected in a spontaneous mode: the backup rate should kick in; check the patient first.

Sudden deterioration = DOPE. Displacement (tube moved — including into the right mainstem), Obstruction (plug, kink, bite), Pneumothorax, Equipment (circuit, valves, water). And the safe first move with ANY unexplained ventilator emergency: look at the patient first; if in doubt, disconnect and hand-bag with 100% oxygen while someone works the DOPE list. Hand-bagging also gives information — a bag that's hard to squeeze points at the lungs/tube, an easy bag with no chest rise points at a leak/displacement.

📖 Source: StatPearls — Ventilator Safety · OpenStax — §35.3 (ETT displacement monitoring)

7. ABG-driven adjustments

Two separate problems, two separate toolboxes — never mix them. Ventilation (CO2) problem → change minute ventilation. Respiratory acidosis (high PaCO2, low pH): increase MV — usually raise the rate first, then Vt if it stays inside lung-protective limits. Respiratory alkalosis (low PaCO2, high pH): decrease MV (lower the rate; in AC, also hunt the cause of over-breathing — pain, fever, anxiety). Oxygenation (O2) problem → FiO2 and PEEP. Think of it as a ladder: FiO2 is fast and simple but toxic at 1.0 for long; PEEP recruits and holds alveoli open, so in ARDS the team often climbs the PEEP rungs rather than parking on FiO2 100%.

Metabolic problems are NOT fixed with the vent. A metabolic acidosis (low HCO3−, e.g. DKA) is treated by treating its cause — insulin and fluids for DKA. The ventilator's job is to protect the airway and support the patient's own compensation, not to blow off enough CO2 to "fix" the pH — chasing the number creates new problems. Ventilator changes treat RESPIRATORY problems.

📖 Source: StatPearls — Ventilator Management (CO2 via Vt/RR; O2 via FiO2/PEEP) · OpenStax — §35.3 (ABG components and interpretation)

8. Weaning & extubation

Weaning starts with a daily readiness screen: the cause of respiratory failure is improving; oxygenation is adequate on modest settings (low FiO2/PEEP); the patient is hemodynamically stable; and they are awake enough to protect their airway. Passing the screen earns a spontaneous breathing trial (SBT) — typically 30 minutes to 2 hours on minimal support (low PS or CPAP) — often paired with a sedation interruption ("sedation vacation").

RSBI (rapid shallow breathing index) = respiratory rate ÷ tidal volume (in litres) during spontaneous breathing. RSBI < 105 predicts success; a rising rate with shrinking volumes (RSBI climbing past 105) is the classic failing pattern. Also weigh: cuff leak (air leaking around a deflated cuff suggests the airway isn't dangerously swollen — absent leak = caution), secretion burden (can they cough and clear?), and mentation. After extubation, high-risk patients often get HFNC or NIV as a bridge. Reintubation risk is highest in the first 24–48 hours — watch work of breathing, rate, and gas exchange, not just SpO2.

📖 Source: StatPearls — Extubation (RSBI < 105, MV < 10 L/min, SBT 30 min–2 h) · OpenStax — §35.3 (SBTs and sedation vacations)

9. Complications & prevention

VAP (ventilator-associated pneumonia) — pneumonia developing more than 48 hours after intubation — is prevented with a bundle: head of bed 30–45°; regular oral care; maintain ETT cuff pressure (about 20–30 cmH2O) and use subglottic suction where available so secretions pooled above the cuff don't leak down; daily sedation vacation + readiness assessment; and DVT and stress-ulcer (GI) prophylaxis — blood thinners and acid suppression, because immobile, critically ill patients clot and bleed.

Lung injury from the vent itself: barotrauma (pressure injury — pneumothorax is the dramatic form) and volutrauma (volume overstretch) are why Vt is prescribed by IBW and plateau pressure is kept under 30. Sedation is titrated to a target on the RASS scale (Richmond Agitation-Sedation Scale) — light is usually better than deep once the patient is stable, because deep sedation prolongs ventilation. Early mobility, even while ventilated, preserves muscle and shortens time on the vent.

📖 Source: OpenStax — §35.3 (VAP bundle; sedation vacations; DVT/ulcer prophylaxis) · StatPearls — Ventilator Safety (HOB 30–45°, cuff 20–30 cmH2O)